SL-FL25 Heat Transfer Index Test Apparatus

Kukuru Apejuwe:

Awọn convective ooru resistance igbeyewo ẹrọ ti wa ni idagbasoke ni ibamu si EN367 ati ISO9151 igbeyewo awọn ajohunše. Awọn opo ti awọn igbeyewo ni lati wiwọn awọn igbeyewo akoko ti a beere fun awọn pada otutu ti awọn ayẹwo si jinde 12 tabi 24 iwọn nipa ikolu ti iná lori isalẹ ti awọn ayẹwo.


  • Min.Order opoiye: 1 kuro
  • Price: negotiable
  • Package: itẹnu Case
  • Awoṣe: SL-FL25
  • Standards: AQ 6103, ISO 9151: 1995, CSN EN 367: 1992
  • ọja Apejuwe

    ọja Tags

    Heat Transfer Index Test Apparatus for Evaluate the Thermal Protection Performance of Protective Clothing Fabrics

    Product introduction of the Ooru Gbe Atọka igbeyewo ohun elo

    A new term heat transfer index (HTI) has been introduced to avoid confusion with the thermal protective index (TPI) or other terms used in previous versions of this test. HTI calculated from the mean time in seconds to achieve a temperature rise of 24±0.2℃ when testing by this method using a copper disc and a starting temperature of 25±5℃. The heat transfer index provides a method of grading materials which does not imply that the material tested will give any precise protective time under actual use conditions.​
    The convective heat resistance test device is developed according to EN367 and ISO9151 test standards, and meets the requirements of the convective heat resistance test standard of domestic AQ 6103-2007 welder protective gloves. The test results are thermal protection index (HTI). The principle of the test is to measure the test time required for the back temperature of the sample to rise 12 or 24 degrees by the impact of flame on the bottom of the sample. The average value of the three tests is recorded as thermal protection index (HTI), which is used to evaluate the thermal protection performance of the protective clothing fabric.

    Ọja  sile ti awọn Ooru Gbe Atọka igbeyewo ohun elo

    Standards AQ 6103, ISO 9151: 1995, CSN EN 367: 1992
    ohun elo Abo Idaabobo
    iwọn 600 * 100 * 600mm (W * H * D)
    àdánù 27KG
    Electrical awọn ibeere 220V, 50HZ
    fifi sori Fume Hood placement
    Time ibiti o 0-100s
    sample iwọn 140 x 140 mm
    Gaasi Orisun ibeere Propane ati Air konpireso Gas
    Calorimeter opin Φ40
    HIV ayika 25 + 5 ℃

    Ọja  Feature of the Ooru Gbe Atọka igbeyewo ohun elo
    O le han ina otutu, odiwon otutu ati akoko digitally.
    Awọn ohun elo ti a ṣe ati ki o ṣelọpọ gẹgẹ EN 367 ati ISO9151 awọn ajohunše.
    Awọn ohun elo oriširiši awọn adiro, awọn ideri dì ati awọn apẹrẹ dimu pẹlu Ejò calorimeter.
    Ideri dì ati awọn apẹrẹ dimu wa ni dari nipasẹ pneumatic gbigbe eyi ti o ti laifọwọyi dari nipa software.
    A nâa Oorun igbeyewo apẹrẹ tunmọ si ohun isẹlẹ ooru isun ti 80KW / ㎡from ọwọ iná ti a Meker adiro nisalẹ o.
    Awọn ooru ran nipasẹ awọn apẹrẹ ti wa ni won nipa ọna ti a kekere Ejò calorimeter lori oke ti o si olubasọrọ pẹlu awọn apẹrẹ.
    Awọn akoko lati gba a otutu jinde ti 12 tabi 24 ℃ ni calorimeter ti wa ni gba silẹ ni aaya.
    Awọn calorimeter itutu ẹrọ si kekere awọn igbeyewo akoko.
    Awọn tumosi esi fun awọn mẹta igbeyewo fun igbeyewo ti wa ni iṣiro bi awọn HTI.
    Awọn odiwọn ti ooru sisan iwuwo ti 80 kW / ㎡is ošišẹ ti laifọwọyi nipa softwa
    Instrument abuda
     Ọja  application of the Ooru Gbe Atọka igbeyewo ohun elo
    Awọn convective ooru resistance igbeyewo ẹrọ fun aabo ohun elo ti wa ni ohun-elo ti o wa ni o kun lo lati wiwọn awọn convective ooru resistance ti hihun, iná ija agbari ati ohun elo miiran.