SL-FL25 Heat Transfer Index Test Apparatus

Whakaahuatanga Poto:

The convective heat resistance test device is developed according to EN367 and ISO9151 test standards. The principle of the test is to measure the test time required for the back temperature of the sample to rise 12 or 24 degrees by the impact of flame on the bottom of the sample.


  • Min.Order Rahi: 1 kōwae
  • Utu: whiriwhiringa
  • Pōkai: kahupapa Case
  • Tauira: SL-FL25
  • Paerewa: AQ 6103、 ISO 9151:1995、CSN EN 367:1992
  • Taipitopito hua

    hua Tags

    Heat Transfer Index Test Apparatus for Evaluate the Thermal Protection Performance of Protective Clothing Fabrics

    Product introduction of the Index Test taputapu Heat Whakawhiti

    A new term heat transfer index (HTI) has been introduced to avoid confusion with the thermal protective index (TPI) or other terms used in previous versions of this test. HTI calculated from the mean time in seconds to achieve a temperature rise of 24±0.2℃ when testing by this method using a copper disc and a starting temperature of 25±5℃. The heat transfer index provides a method of grading materials which does not imply that the material tested will give any precise protective time under actual use conditions.​
    The convective heat resistance test device is developed according to EN367 and ISO9151 test standards, and meets the requirements of the convective heat resistance test standard of domestic AQ 6103-2007 welder protective gloves. The test results are thermal protection index (HTI). The principle of the test is to measure the test time required for the back temperature of the sample to rise 12 or 24 degrees by the impact of flame on the bottom of the sample. The average value of the three tests is recorded as thermal protection index (HTI), which is used to evaluate the thermal protection performance of the protective clothing fabric.

    Hua  tawhā o te Index Test taputapu Heat Whakawhiti

    paerewa AQ 6103, ISO 9151: 1995, CSN EN 367: 1992
    Taupānga Parenga haumaru
    rahi 600 * 100 * 600mm (W * H * D)
    Taumaha 27KG
    whakaritenga Electrical 220V, 50HZ
    tāutanga whakanohonga autahu'araa Fume
    ngā Time 0-100s
    rahi tauira 140 x 140 mm
    Whakaritenga Gas Pūtake Pōwaro me Air Compressor Gas
    Calorimeter diameter Φ40
    taiao Testing 25 + 5 ℃

    Hua  Feature of the Index Test taputapu Heat Whakawhiti
    e taea te whakaatu te reira i te pāmahana mura, mehua pāmahana me te wā-mamati.
    Hangaia te taputapu kei te ka hangaia rite ki EN 367 me ISO9151 paerewa.
    Kei te taputapu o te muratahi, te whārangi uwhi me te taata tei mau tauira ki parahi calorimeter.
    E whakahaeretia ana te whārangi uwhi me te taata tei mau tauira mā te tuku whāhauhau i te whakahaeretia aunoa i te pūmanawa.
    He tauira whakamātautau whakapae hāngai i raro ki te rere o 80KW wera maiki / ㎡from te mura o te muratahi Meker raro reira.
    Whanganga te wera haere i roto i te tauira e te tikanga o te calorimeter parahi iti i runga i te tihi o me te whakapā ki te tauira.
    Ko te wa ki te tuhi i te pāmahana ara o 12 ranei 24 ℃ i roto i te calorimeter tuhia i roto i hēkona.
    Ko te pūrere calorimeter meangiti whakapoto i te wā whakamātautau.
    Tatau te hua toharite mō te tauira whakamātautau e toru kei te rite te HTI.
    Ko te whakatika o te rere wera kiato o 80 Kw / ㎡is whakamana aunoa e softwa
    Instrument āhuatanga
     Hua  application of the Index Test taputapu Heat Whakawhiti
    Ko te pūrere whakamātau resistance wera convective mō rauemi tiaki ko te mea te nuinga te i whakamahia ki te ine i te ātete wera convective o papanga, kai whawhai ahi me ētahi atu rauemi.