SL-FL25 Heat Transfer Index Test Apparatus
Heat Transfer Index Test Apparatus for Evaluate the Thermal Protection Performance of Protective Clothing Fabrics
Product introduction of the Pemindahan Haba Ujian Indeks Apparatus
A new term heat transfer index (HTI) has been introduced to avoid confusion with the thermal protective index (TPI) or other terms used in previous versions of this test. HTI calculated from the mean time in seconds to achieve a temperature rise of 24±0.2℃ when testing by this method using a copper disc and a starting temperature of 25±5℃. The heat transfer index provides a method of grading materials which does not imply that the material tested will give any precise protective time under actual use conditions.
The convective heat resistance test device is developed according to EN367 and ISO9151 test standards, and meets the requirements of the convective heat resistance test standard of domestic AQ 6103-2007 welder protective gloves. The test results are thermal protection index (HTI). The principle of the test is to measure the test time required for the back temperature of the sample to rise 12 or 24 degrees by the impact of flame on the bottom of the sample. The average value of the three tests is recorded as thermal protection index (HTI), which is used to evaluate the thermal protection performance of the protective clothing fabric.
Produk parameter Pemindahan Haba Ujian Indeks Apparatus
piawaian | AQ 6103, ISO 9151: 1995, CSN EN 367: 1992 |
permohonan | Perlindungan keselamatan |
saiz | 600 * 100 * 600mm (W * H * D) |
Berat | 27kg |
keperluan elektrik | 220V, 50HZ |
pemasangan | penempatan hud wasap |
julat masa | 0-100s |
Saiz sampel | 140 x 140 mm |
Keperluan Gas Sumber | Propana dan Air Compressor Gas |
diameter meter kalori | Φ40 |
persekitaran ujian | 25 + 5 ℃ |
Produk Feature of the Pemindahan Haba Ujian Indeks Apparatus
Ia boleh memaparkan suhu api, suhu ukuran dan masa digital.
Alat yang direka dan dikilangkan mengikut EN 367 dan ISO9151 standard.
Radas terdiri daripada pembakar, luar kulit dan pemegang spesimen dengan kalorimeter tembaga.
Lembaran perlindungan dan pemegang spesimen dikawal melalui penghantaran pneumatik yang dikawal secara automatik oleh perisian.
A spesimen ujian mendatar berorientasikan tertakluk kepada fluks kejadian haba 80KW / ㎡from api pembakar Meker bawahnya.
Haba melalui spesimen diukur dengan menggunakan suatu kalorimeter tembaga kecil di atas dan hubungan dengan spesimen.
Masa untuk mencatatkan kenaikan suhu 12 atau 24 ℃ dalam meter kalori direkodkan dalam saat.
Peranti kalorimeter penyejukan memendekkan masa ujian.
Hasil min bagi tiga spesimen ujian dikira sebagai HTI itu.
Penentukuran ketumpatan aliran haba 80 kW / ㎡is dilakukan secara automatik oleh softwa
Instrument Ciri-ciri
Produk application of the Pemindahan Haba Ujian Indeks Apparatus
Perolakan rintangan haba alat ujian untuk bahan-bahan perlindungan adalah satu instrumen yang digunakan terutamanya untuk mengukur rintangan haba perolakan tekstil, peralatan memadam kebakaran dan bahan-bahan lain.