China SL-FL25 Heat Transfer Index Test Apparatus Manufacturers and Suppliers | Skyline
industrial sewing machine

SL-FL25 Heat Transfer Index Test Apparatus

Faamatalaga puupuu:

The convective heat resistance test device is developed according to EN367 and ISO9151 test standards. The principle of the test is to measure the test time required for the back temperature of the sample to rise 12 or 24 degrees by the impact of flame on the bottom of the sample.


  • Min.Order Aotelega: 1 iunite
  • Tau: o feagaiga tau tupe
  • Afifi: Mataupu Plywood
  • Faataitaiga: SL-FL25
  • Tulaga Faatonuina: AQ 6103、 ISO 9151:1995、CSN EN 367:1992
  • Faamatalaga oloa

    pine o oloa

    Heat Transfer Index Test Apparatus for Evaluate the Thermal Protection Performance of Protective Clothing Fabrics

    Product introduction of the Faaliliuina vevela Totoga Faasino Upu Tofotofoga

    A new term heat transfer index (HTI) has been introduced to avoid confusion with the thermal protective index (TPI) or other terms used in previous versions of this test. HTI calculated from the mean time in seconds to achieve a temperature rise of 24±0.2℃ when testing by this method using a copper disc and a starting temperature of 25±5℃. The heat transfer index provides a method of grading materials which does not imply that the material tested will give any precise protective time under actual use conditions.​
    The convective heat resistance test device is developed according to EN367 and ISO9151 test standards, and meets the requirements of the convective heat resistance test standard of domestic AQ 6103-2007 welder protective gloves. The test results are thermal protection index (HTI). The principle of the test is to measure the test time required for the back temperature of the sample to rise 12 or 24 degrees by the impact of flame on the bottom of the sample. The average value of the three tests is recorded as thermal protection index (HTI), which is used to evaluate the thermal protection performance of the protective clothing fabric.

    Oloa  le faataamilosaga o le Faaliliuina vevela Totoga Faasino Upu Tofotofoga

    tulaga faatonuina AQ 6103, ISO 9151: 1995, CSN IT 367: 1992
    talosaga saogalemu Puipuiga
    fua 600 * 100 * 600mm (W * H * D)
    mamafa 27KG
    manaoga eletise 220V, 50HZ
    oʻo aoga Hood Fume
    taimi eseese 0-100s
    tele faataitaiga 140 x 140 mm
    Manaoga Puna kasa Alu i le kesi ma Air kasa Compressor
    Calorimeter lapoa Φ40
    siosiomaga suʻega 25 + 5 ℃

    Oloa  Feature of the Faaliliuina vevela Totoga Faasino Upu Tofotofoga
    E mafai ona faaalia vevela mumū, fua vevela ma le taimi digitally.
    Ua mamanuina le meafaigaluega ma gaosia e tusa ma IT 367 ma ISO9151 tulaga faatonuina.
    E aofia ai le masini o le burner, le faavaa pepa ma o lo o umia mo suesuega ma calorimeter apamemea.
    O loo pulea le faavaa pepa ma o lo o umia mo suesuega e ala i le auina atu pneumatic lea e otometi lava ona pulea e o polokalama faakomepiuta.
    A faalava taulai mo suesuega suega noatia i se flux vevela mea na tupu o 80KW / ㎡from le afi o se burner Meker i lalo ifo.
    Le vevela ui atu i le toto mo suesuega ua fuaina e ala i se calorimeter laiti apamemea i luga o le ma fesootaiga ma le toto mo suesuega.
    O le taimi e faamaumau ai se vevela tulai mai o le 12 po o le 24 ℃ i le calorimeter o loo tusia i sekone.
    Faapuupuu le masini calorimeter cooling le taimi suega.
    O le taunuuga leaga mo le specimens suega e tolu ua fuafuaina e pei o le HTI.
    O le calibration o density tafe vevela o 80 kW / ㎡is faia otometi e softwa
    uiga Tufugaaao
     Oloa  application of the Faaliliuina vevela Totoga Faasino Upu Tofotofoga
    Le masini suega tetee vevela convective mo mea e puipuia ai o se pepa faale-tulafono lea ua mafua faaaoga e fua ai le tetee vevela convective o le ie, o le afi sapalai taua ma isi mea.


  • Talu:
  • Sosoo ai:

  • Tusi lau savali iinei ma auina mai ia i tatou
    industrial sewing machine