SL-FL29 Oxygen Bomb Calorimeter
Oxygen Ibhomu Calorimeter / Buliding Izinto Burning calorific Value Tester
Umkhiqizo ukwethulwa Oxygen Ibhomu Calorimeter
Kuyinto yokwakha izinto omlilo calorific ukubaluleka kokuhlolwa. Indlela yokuhlola elicacisiwe le ndinganiso isetshenziswa ukuhlola ngokuphelele Ukushisa ukubaluleka amandla omlilo of the sihloko test kungakhathaliseki morphology we sihloko
Amazinga
ISO1716, EN ISO 1716
Umkhiqizo incazelo we mpilo Ibhomu Calorimeter
ibhomu Umthamo | (300 ± 50) ml |
Oxygen ibhomu ingcindezi ububanzi | 0.5 ~ 3.5MPa, akukho ukuvuza, ibhomu ingcindezi 21Mpa |
Iziko | Φ25mm, ukuphakama (14-19) mm, ukushuba udonga 1mm. Insimbi engagqwali |
amandla eshukumisayo | 0.5KW |
imvelo Isicelo | (10 ~ 35) ℃, umswakama ≤80% |
Heat umthamo | mayelana 10000J / K |
Repeatability ukushisa umthamo | ≤0.2% |
Temperature ukuthola | (4.5-50) ℃, 0,0001 ℃ isinqumo |
Izinga lokushisa inzwa | PT100 |
isilinda Inner | 2000ml |
Oxygen ibhomu ukubekwa uphawu | oxygenation ingcindezi 2.5 ~ 3.5MPa, akukho ukuvuza |
amandla eshukumisayo | 3W, 375r / iminithi |
Ukunikezwa kwamandla kagesi | AC220V ± 10% 50Hz |
Izici Product mpilo Ibhomu Calorimeter
- Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
- Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate
- Meet the international standard "end of the barrel than the outer cylinder about 1K"
- computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value
- Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
- microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.
Bhala umyalezo wakho lapha futhi ulithumele kithi