SL-FL29 Oxygen Bomb Calorimeter
Hāora Bomb Calorimeter / Buliding Materials Weranga Calorific Uara Kaiwhakamātau
introduction Hua o te hāora Bomb Calorimeter
Ko reira hoki hanga rauemi parariraa uara calorific whakamātautau. Ko te tikanga whakamātautau tohua i roto i tenei paerewa whakamahia te ki te whakamatautau i te uara whakawera pū o te ngingiha o te tuhinga whakamātautau ahakoa o te Morphology o te tuhinga
paerewa
ISO1716, EN ISO 1716
Hua Whakapūtātanga o te hāora Bomb Calorimeter
Raukaha Bomb | (300 ± 50) mL |
Hāora awhe pēhanga poma | 0.5 ~ 3.5MPa, kahore leakage, pēhanga poma 21Mpa |
para | Φ25mm, teitei (14-19) mm, he matotoru taiepa o 1mm. he kowiri tira |
mana faaururaa | 0.5KW |
taiao Taupānga | (10 ~ 35) ℃, haumākū ≤80% |
kaha Heat | e pā ana ki 10000J / K |
Repeatability o te kaha wera | ≤0.2% |
Temperature rapunga | (4.5-50) ℃, 0,0001 ℃ taumira |
Temperature pūoko | PT100 |
puoto Inner | 2000ml |
Hāora te taatiraa poma | pēhanga oxygenation 2.5 ~ 3.5MPa, kahore leakage |
mana faaururaa | 3W, 375r / min |
supply Power | AC220V ± 10% 50Hz |
Āhuatanga Hua o te hāora Bomb Calorimeter
- Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
- Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate
- Meet the international standard "end of the barrel than the outer cylinder about 1K"
- computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value
- Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
- microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.
Tuhia tō karere i konei, ka tukua atu i te reira ki a tatou