SL-FL29 Oxygen Bomb Calorimeter
Oksigeno Bomb calorímetro / Buliding Materialoj Burning calorífica Valoro Tester
Produkta enkonduko de la oksigeno Bomb calorímetro
Estas por konstruado materialoj brulado calorífica valoron testo. La testo metodo specifita en ĉi tiu normo estas uzata por testi la absoluta hejtado valoro de la brulado de la testo artikolo sendepende de la morfologio de la artikolo
normoj
ISO1716, EN ISO 1716
Produkto Specification de la oksigeno Bomb calorímetro
bombo Kapacito | (300 ± 50) ml |
Oksigeno bombo premo gamo | 0.5 ~ 3.5MPa, ne leakage, bombo premo 21Mpa |
fandujo | Φ25mm, alteco (14-19) mm, muro dikeco de 1mm. Senrusta ŝtalo |
instiganta povo | 0.5KW |
apliko medio | (10 ~ 35) ℃, humido ≤80% |
varmo kapablo | pri 10000J / K |
Repetibilidad de varmo kapablo | ≤0.2% |
temperaturo malkaŝo | (4.5-50) ℃, 0,0001 ℃ distingivo |
temperaturo sensor | PT100 |
interna cilindro | 2000ml |
Oksigeno bombo Sealing | oxigenación premo 2.5 ~ 3.5MPa, ne leakage |
instiganta povo | 3W, 375r / min |
Fonto de nutrado | AC220V ± 10% 50Hz |
Produkto Trajtoj de la oksigeno Bomb calorímetro
- Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
- Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate
- Meet the international standard "end of the barrel than the outer cylinder about 1K"
- computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value
- Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
- microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.