SL-FL29 Oxygen Bomb Calorimeter
Okesene pomu Calorimeter / Buliding Mea Tester mu Calorific Taua
faatomuaga oloa o le okesene pomu Calorimeter
E mo le fausiaina o mea suega taua calorific combustion. O le auala suega faamaoti mai i lenei tulaga o loo faaaogaina e tofotofo le taua faʻavevela aiai o le combustion o le tusiga tofotofoga e tusa lava po o le morphology o le tusiga
tulaga faatonuina
ISO1716, IT ISO 1716
Oloa Specification o le okesene pomu Calorimeter
pomu le mafai gafatia | (300 ± 50) mL |
Okesene tele omiga pomu | 0.5 ~ 3.5MPa, e leai se leakage, 21Mpa uunaiga pomu |
tofotofoga faigata | Φ25mm, maualuga (14-19) mm, o se puipui mafiafia o 1mm. Apa siliva |
mana musuia | 0.5KW |
siosiomaga talosaga | (10 ~ 35) ℃, sūsū ≤80% |
tulaga vevela | e uiga i 10000J / K |
Repeatability o tulaga vevela | ≤0.2% |
vevela mauaina | (4.5-50) ℃, 0,0001 ℃ iugafono |
vevela sensor | PT100 |
ogāumu totonu | 2000ml |
Faamauga pomu okesene | oxygenation uunaiga 2.5 ~ 3.5MPa, e leai se leakage |
mana musuia | 3W, 375r / min |
Paoa sapalai | AC220V ± 10% 50Hz |
Features oloa o le okesene pomu Calorimeter
- Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
- Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate
- Meet the international standard "end of the barrel than the outer cylinder about 1K"
- computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value
- Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
- microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.