China SL-FL29 Oxygen Bomb Calorimeter Manufacturers and Suppliers | Skyline
industrial sewing machine

SL-FL29 Oxygen Bomb Calorimeter

Deskrizzjoni fil-qosor:

Huwa għal materjali tal-bini Kriterju tal-valur kalorifiku kombustjoni. Il-metodu tat-test speċifikat f'dan l-istandard jintuża sabiex jiġu ttestjati l-valur tat-tisħin assolut tal-kombustjoni tal-oġġett tat-test irrispettivament mill-morfoloġija ta 'l-artikolu


  • Min.order Kwantità: 1 unità
  • Prezz: negozjabbli
  • Pakkett: Plywood Kawża
  • Mudell: SL-FL29
  • Istandards: ISO1716, EN ISO 1716
  • Dettall tal-prodott

    prodott Tags

    Ossiġnu Bomb Calorimeter / Buliding Materjali Ħruq Valur Kalorifiku Instron

    introduzzjoni tal-prodott tal-ossiġnu 'Bomb Calorimeter

    Huwa għal materjali tal-bini Kriterju tal-valur kalorifiku kombustjoni. Il-metodu tat-test speċifikat f'dan l-istandard jintuża sabiex jiġu ttestjati l-valur tat-tisħin assolut tal-kombustjoni tal-oġġett tat-test irrispettivament mill-morfoloġija ta 'l-artikolu

    istandards

    ISO1716, EN ISO 1716

    Speċifikazzjoni tal-Prodott tal-  ossiġnu 'Bomb Calorimeter

     Bomb Kapaċità  (300 ± 50) mL
     Ossiġnu firxa ta 'pressjoni bomba  0.5 ~ 3.5MPa, ebda tnixxija, pressjoni bomba 21Mpa
     crucible  Φ25mm, għoli (14-19) mm, ħxuna tal-ħajt ta '1mm. Stainless steel
     enerġija tħawwad  0.5KW
     ambjent applikazzjoni  (10 ~ 35) ℃, umdità ≤80%
     kapaċità tas-sħana  dwar 10000J / K
     Repetibbiltà tal-kapaċità tas-sħana  ≤0.2%
     sejbien temperatura  (4.5-50) ℃, 0.0001 ℃ riżoluzzjoni
     sensur tat-temperatura  PT100
     ċilindru ġewwa  2000ml
     Ossiġnu Siġillar bomba  pressjoni ossiġinazzjoni 2.5 ~ 3.5MPa, l-ebda tnixxija
     enerġija tħawwad  3W, 375r / min
     provvista ta 'enerġija  AC220V ± 10% 50Hz

    Prodott Karatteristiċi ta 'l  ossiġnu 'Bomb Calorimeter

    1. Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
    2. Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate  
    3. Meet the international standard "end of the barrel than the outer cylinder about 1K"
    4. computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value  
    5. Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
    6. microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.

  • Preċedenti:
  • Li jmiss:

  • Ikteb messaġġ tiegħek hawn u jibagħtu lill magħna