SL-FL29 Oxygen Bomb Calorimeter
Sauerstoff Bomb Calorimeter / Buliding spontan Burning Calorific gëllt Tester
Produit Aféierung vun de Sauerstoff Bomb Calorimeter
Et ass fir Material Verbrennungsmotor calorific Wäert Test Gebai. D'Test Method an dësem Standard uginn ass benotzt den absolute Heizung Wäert vun de Verbrennungsmotor vum Test Artikel ze Test egal vum grousse Ganzen vun der Manifestatioun
Standarden
ISO1716, EN ISO 1716
Produit Spezifizéierung vum Web- Bomb Calorimeter
bomb Kapazitéit | (300 ± 50) ML |
Sauerstoff bomb Drock Rei | 0,5 ~ 3.5MPa, keen Auswee, bomb Drock 21Mpa |
Dës Säit | Φ25mm, Héicht (14-19) mm, eng Mauer deck 1mm. Edelstol |
réieren Muecht | 0.5KW |
Applikatioun Ëmwelt | (10 ~ 35) ℃, Fiichtegkeet ≤80% |
Hëtzt Muecht | iwwer 10000J / K |
Repeatability vun Hëtzt Muecht | ≤0.2% |
Temperatur erkennen | (4.5-50) ℃, 0,0001 ℃ Resolutioun |
Temperatur Sensor | PT100 |
zentrale losen | 2000ml |
Sauerstoff bomb wier | oxygenation Drock 2,5 ~ 3.5MPa, keen Auswee |
réieren Muecht | 3W, 375r / min |
Stroumversuergung | AC220V ± 10% 50Hz |
Produit Charakteristike vu de Web- Bomb Calorimeter
- Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
- Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate
- Meet the international standard "end of the barrel than the outer cylinder about 1K"
- computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value
- Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
- microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.
Schreiwen Äre Message hei a schéckt et eis