SL-FL29 Oxygen Bomb Calorimeter
Oxygen calorímetro de bomba / buliding Obras queima calorífico Tester
introdución do produto do osíxeno bomba calorímetro
E para a construción de materiais de proba de poder calorífico de combustión. O método de ensaio especificado na norma é usada para probar o valor absoluto de calefacción a combustión do artigo de proba, con independencia da morfoloxía do artigo
Standards
ISO1716, UNE-EN ISO 1716
Especificación de produto da Oxygen calorímetro de bomba
bomba Capacidade | (300 ± 50) ml |
Oxygen franxa de presión de bomba | 0,5 ~ 3.5MPa, sen fugas, a presión da bomba 21Mpa |
placa | Φ25mm, altura (14-19) mm, un grosor de parede de 1 mm. Aceiro inoxidable |
potencia de axitación | 0.5KW |
ambiente de aplicación | (10 ~ 35) ℃, humidade ≤80% |
capacidade de calor | sobre 10000J / K |
Repetibilidade de capacidade de calor | ≤0.2% |
detección de temperatura | (4,5-50) ℃, 0,0001 ℃ resolución |
O sensor de temperatura | PT100 |
cilindro interno | 2000ml |
Oxygen Sealing bomba | presión oxixenación 2,5 ~ 3.5MPa, ningunha fuga |
potencia de axitación | 3W, 375r / min |
Fonte de alimentación | AC220V ± 10% 50Hz |
Características do produto do Oxygen calorímetro de bomba
- Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
- Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate
- Meet the international standard "end of the barrel than the outer cylinder about 1K"
- computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value
- Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
- microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.
Escribe aquí a túa mensaxe e enviala para nós