SL-FL29 Oxygen Bomb Calorimeter
Ogsaidsean Bomb Calorimeter / Stuthan Buliding Burning Calorific Luach Tester
Bathar a 'toirt a-steach ogsaidsean Bomb Calorimeter
Tha e airson 'togail stuthan losgaidh calorific luach deuchainn. Tha an deuchainn dòigh a shònrachadh ann an ìre seo air a chleachdadh airson deuchainn iomlan a 'teasachadh luach an losgaidh na deuchainn artaigil a dh'aindeoin dè an morf-eòlas na h-aiste
Inbhean
ISO1716, EN ISO 1716
Bathar Sònrachadh an ogsaidsean Bomb Calorimeter
Bomb Comas | (300 ± 50) ML |
Ogsaidsean Boma Brùthadh raon | 0.5 ~ 3.5MPa, cha aoidionachd, Boma Brùthadh 21Mpa |
Crucible | Φ25mm, àirde (14-19) mm, balla tighead de 1mm. Stàilinn nach meirg |
brodadh cumhachd | 0.5KW |
Iarrtas an àrainneachd | (10 ~ 35) ℃, Taiseachd ≤80% |
Heat comas | mu 10000J / K |
Repeatability teas comas | ≤0.2% |
Teòthachd lorgaidh | (4.5-50) ℃, 0,0001 ℃ rùn |
Teòthachd sensor | PT100 |
-staigh siolandair | 2000ml |
Ogsaidsean Boma seulachadh | ogsaidean Brùthadh 2.5 ~ 3.5MPa, cha aoidionachd |
brodadh cumhachd | 3W, 375r / min |
Solar cumhachd | AC220V ± 10% 50Hz |
Bathar Feartan ogsaidsean Bomb Calorimeter
- Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
- Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate
- Meet the international standard "end of the barrel than the outer cylinder about 1K"
- computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value
- Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
- microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.