SL-FL29 Oxygen Bomb Calorimeter
Oksijene Bomb Calorimeter / Buliding Materials Tukang lik'halori tse Bohlokoa mohlahlobi
Product selelekela tsa oksijene Bomb Calorimeter
Ho bakeng sa ho haha thepa combustion e lik'halori boleng teko. Teko mokhoa boletsweng tekanyetso ena e sebediswa hore a leke ho feletseng futhumatsang boleng ba combustion ea sehlooho teko ho sa tsotellehe phetoho ea sehlooho se reng,
litekanyetso tsa hae
ISO1716, EN ISO 1716
Product ga tlhaloso ea oksijene Bomb Calorimeter
bomo bokgoni | (300 ± 50) ML |
Oksijene bomo khatello ea mefuta e fapaneng | 0.5 ~ 3.5MPa, ha ho dutla, bomo khatello ea 21Mpa |
tsoana le sebopi | Φ25mm, bophahamo (14-19) limilimithara, lerako botenya ba 1mm. Ts'epe e sa beng le mabali |
matla a susumetsang | 0.5KW |
tikoloho ya kopo | (10 ~ 35) ℃, mongobo ≤80% |
mocheso bokgoni | ka 10000J / K |
Repeatability ya bokgoni mocheso | ≤0.2% |
mocheso bonoa | (4.5-50) ℃, 0,0001 ℃ qeto |
mocheso kutlo | PT100 |
silindara Inner | 2000ml |
Oksijene bomo tiisoa | oxygenation khatello ea 2,5 ~ 3.5MPa, ha ho dutla |
matla a susumetsang | 3mon, 375r / mets |
Phepelo ea motlakase | AC220V ± 10% 50Hz |
Product Features tsa oksijene Bomb Calorimeter
- Automatic control of the outer cylinder water temperature at the set point temperature, to ensure that changes in real temperature does not affect the cooling correction, the measurement results more accurate
- Automatically adjust the temperature inside and outside the cylinder, the use of a unique cooling correction system, water circulation system and software error correction system to reduce the cooling correction, the measurement results more accurate
- Meet the international standard "end of the barrel than the outer cylinder about 1K"
- computer calorific value calorimeter, to maintain the full functionality of the microcomputer system can run common software for other transactions, and start calorimeter measurement system can automatically calibrate the calorimeter energy equivalent (heat capacity), measure the calorific value
- Computerized combustion calorimeter The inner cylinder of the device adopts the electric stirring of the paddle blade, and the mixing of the outer cylinder adopts the submersible electric stirring to make the stirring more even and convenient. The instrument uses a blown cotton ignition method.
- microcomputer calorific value tester operating in WinsowsXP and above operating system, the whole process of Chinese characters prompts, human-computer interaction, that is, learning to use, follow the prompts to complete the test.