Lachin lafimen Dansite Chanm Konpayi fabrikasyon yo ak Founisè | Skyline
industrial sewing machine

Lafimen Dansite Chanm

Kout Deskripsyon:

te enstriman sa a te etabli pou anpil ane epi li se itilize lajman nan tout sektè endistriyèl pou detèminasyon an nan lafimen ki te pwodwi pa materyèl solid ak nan asanble monte nan yon pozisyon nan vètikal nan yon chanm fèmen.


  • Min.Order Kantite: 1 inite
  • Prix: Negosyab
  • PACKAGE: Plywood Ka
  • Modèl: SL838
  • Standards: AITM 2.0007A,AITM 2.0007B,AITM 3.0005、BSS 7238,BSS 7239、FAR PART 25 APPENDIX F Part V
  • pwodwi Detay

    pwodwi baj

    Smoke Density Chamber Electronic ignition system with PID temperature controller Analysis of various gases

    Pwodwi Profile  of Lafimen Dansite Chanm

    te enstriman sa a te etabli pou anpil ane epi li se itilize lajman nan tout sektè endistriyèl pou detèminasyon an nan lafimen ki te pwodwi pa materyèl solid ak nan asanble monte nan yon pozisyon nan vètikal nan yon chanm fèmen.

    Pwodwi  paramèt  nan  Lafimen Dansite Chanm

     Kantite moun ki  1560 mm (W) x 2220 mm x (H) x 1060 mm
     Pwa  190KG
     Standards  AITM 2.0007A,AITM 2.0007B,AITM 3.0005、BSS 7238,BSS 7239、FAR PART 25 APPENDIX F Part V
     aplikasyon  Aviation 
     Elektrik  110V AC 60Hz / 230V AC 50Hz, 15A
     Anbyen Tanperati  Operating 10°C to 35°C

     

    Product Feature nan  Lafimen Dansite Chanm

    Powder coated liner removable for repair/replacement. Powder coated exterior.
    Large tempered double glazed door for easy viewing and cleaning.
    PID temperature controller for constant furnace setting.
    Coil type tubular radiant heater with integrated thermocouple. Master electrical shut-off switch with maintenance lockout. Pneumatic actuated test sample transport system for repeatability of tests.
    Electronic ignition system.
    Calibrated flowmeters Propane and air flow measurement. Master gas on/off control with safety latching circuit to prevent gas flow following power interruption.
    2 removable 6 flame pilot burners for normal test and wire test. 4 ports on roof of chamber for toxicity analysis.
    3 stainless steel sample holders complete with backer board, spring and spring pin.
    1 blank sample for wall protection. Wire sample holder
    Calibration system including 1 water cooled heat flux gauge (0-5 W/cm2), holder and integral cooling system.
    3 optical filters for linearity calibration.
    Furnace location and pilot burner location tools. Pilot burner cleaning tool.
    Customized data acquisition software and hardware for calibration and testing with USB interface for connection to external computer (administration rights required for computer)
    Data stored in csv format for easy exporting to spreadsheet programs.

    Spare parts kit including

    À fotomultiplikateur tib lanp
    Standard pilòt brûler
    Pòt sele
    vantilasyon sele
    Anpeche mother
    emisyon gaz fanatik
    gaz / lè solenoid solenoyid
    Fuse twous
    sistèm òdinatè pa enkli men yo ka apwovizyone si requeste

     


  • Previous:
  • Next:

  • Ekri mesaj ou a isit la epi voye li nan nou
    industrial sewing machine