China Anwụrụ ọkụ njupụta Chamber Manufacturers na Suppliers | skyline
industrial sewing machine

Anwụrụ ọkụ njupụta Chamber

Short Description:

Nke a ngwá e guzosie ike ruo ọtụtụ afọ na a na-eji ọtụtụ ebe niile na ulo oru ndi maka mkpebi siri ike nke na-ese N'ịbụ siri ike ihe na mgbakọ dị iche n'ịnyịnya na vetikal ọnọdụ n'ime a mechiri emechi ụlọ.


  • Min.Order ibu: 1 unit
  • Ahịa: Okwukwe
  • Ngwugwu: Plywood Case
  • Model: SL838
  • Standards: AITM 2.0007A,AITM 2.0007B,AITM 3.0005、BSS 7238,BSS 7239、FAR PART 25 APPENDIX F Part V
  • Product Ihe

    Product Tags

    Smoke Density Chamber Electronic ignition system with PID temperature controller Analysis of various gases

    Product Profile  of Anwụrụ ọkụ njupụta Chamber

    Nke a ngwá e guzosie ike ruo ọtụtụ afọ na a na-eji ọtụtụ ebe niile na ulo oru ndi maka mkpebi siri ike nke na-ese N'ịbụ siri ike ihe na mgbakọ dị iche n'ịnyịnya na vetikal ọnọdụ n'ime a mechiri emechi ụlọ.

    Product  parameters  nke  Anwụrụ ọkụ njupụta Chamber

     size  1560 mm (W) x 2220 mm x (H) x 1060 mm
     ibu  190KG
     Standards  AITM 2.0007A,AITM 2.0007B,AITM 3.0005、BSS 7238,BSS 7239、FAR PART 25 APPENDIX F Part V
     ngwa  Aviation 
     Ọdụdọ  110V AC 60Hz / 230V AC 50Hz, 15A
     ihere okpomọkụ  Operating 10°C to 35°C

     

    Product Feature nke  Anwụrụ ọkụ njupụta Chamber

    Powder coated liner removable for repair/replacement. Powder coated exterior.
    Large tempered double glazed door for easy viewing and cleaning.
    PID temperature controller for constant furnace setting.
    Coil type tubular radiant heater with integrated thermocouple. Master electrical shut-off switch with maintenance lockout. Pneumatic actuated test sample transport system for repeatability of tests.
    Electronic ignition system.
    Calibrated flowmeters Propane and air flow measurement. Master gas on/off control with safety latching circuit to prevent gas flow following power interruption.
    2 removable 6 flame pilot burners for normal test and wire test. 4 ports on roof of chamber for toxicity analysis.
    3 stainless steel sample holders complete with backer board, spring and spring pin.
    1 blank sample for wall protection. Wire sample holder
    Calibration system including 1 water cooled heat flux gauge (0-5 W/cm2), holder and integral cooling system.
    3 optical filters for linearity calibration.
    Furnace location and pilot burner location tools. Pilot burner cleaning tool.
    Customized data acquisition software and hardware for calibration and testing with USB interface for connection to external computer (administration rights required for computer)
    Data stored in csv format for easy exporting to spreadsheet programs.

    Spare parts kit including

    Oku Photomultiplier tube Oriọna
    Standard pilot burner
    Door akara
    ekupụ akàrà
    ekupụ actuator
    iyuzucha ofufe
    Gas / ikuku solenoid
    gwakọta kit