Lachin OSU Chalè Release To tèsteur Konpayi fabrikasyon yo ak Founisè | Skyline

OSU Chalè Release To tèsteur

Kout Deskripsyon:

te OSU chalè to lage tèsteur la ki te apwouve pa FAA nan Administrasyon an Aviyasyon Federal nan peyi Etazini orijinal ki fèt pa Smith nan Ohio State University nan lane 1972, epi pita te vin tounen yon enstriman FAA deziyen tès ki degaje konbisyon pou fè tès to a lage chalè nan materyèl Aewonotik.


  • Min.Order Kantite: 1 inite
  • Prix: Negosyab
  • PACKAGE: Plywood Ka
  • Modèl: SL833
  • Standards: AITM 2,0006, BSS 7322, byen lwen PATI 25 APENDIS F Pati IV
  • pwodwi Detay

    pwodwi baj

    OSU Heat Release Rate Tester Stainless Steel Combustion Test Chamber Equipped

    Pwodwi enfòmasyon  nan OSU hHeat Release To tèsteur

    The OSU heat release rate tester approved by FAA of the Federal Aviation Administration of the United States was originally designed by Smith of Ohio State University in 1972, and later became a FAA designated combustion test instrument for testing the heat release rate of Aeronautical materials. The test standards are FAR Part 25 Appendix F Part IV, Airbus AITM 2.00. 06, Boeing BSS 7322.

    Karakteristik pèfòmans nan OSU Chalè Release To tèsteur

    1. Stainless steel combustion test chamber with high temperature glass observation window;
    2. The heat radiation source is 4 Glowbars heating rods, which can provide 35KW/M2 heat radiation flux.
    3. Two independent PID temperature controllers are used for heating temperature control.
    4. Equipped with fully automatic pneumatic sample propulsion device and shielding door device;
    5. Equipped with upper burner and movable lower burner;
    6. Rotor flowmeter can be used to adjust the gas flow rate of upper and lower burners.
    7. Equipped with movable T-type calibration burner device and flow controller;
    8. Mass flow controller is applied to thermopile temperature calibration automatically.
    9. Water-cooled heat flow meter is equipped with cooling mode to measure the heat radiation flux of the fire surface.
    10. The air temperature control device can provide constant temperature and flow air for the test chamber.
    11. The orifice flowmeter is used to measure the flow pressure entering the test bin.
    12. Equipped with data acquisition system and heat release standard test software.

    Pwodwi  paramèt of OSU Heat Release Rate Tester

     Kantite moun ki  760mm (W) x 1850mm x (H) x 850mm (D)
     Pwa  218KG
     elektrisite kondisyon  220 V, 35 anpli
     tanperati anbyen  10 ℃ a 35 ℃
     oksilyè gaz  Constant Tanperati ak Constant gaz Kouran
     ki degaje konbisyon gaz  metàn
     Standard   AITM 2,0006, BSS 7322, byen lwen PATI 25 APENDIS F Pati IV
     Aplikasyon  Aviyasyon Materyèl

     


  • Previous:
  • Next:

  • Ekri mesaj ou a isit la epi voye li nan nou