China OSU Heat Release Kadar Tester Manufacturers and Suppliers | Skyline

OSU Heat Kadar Tester Release

Penerangan Ringkas:

The OSU kadar pembebasan haba tester diluluskan oleh FAA Pentadbiran Penerbangan Persekutuan Amerika Syarikat pada asalnya direka oleh Smith dari Ohio State University pada tahun 1972, dan kemudian menjadi pembakaran ujian instrumen FAA ditetapkan untuk menguji kadar pelepasan haba bahan Aeronautical.


  • Min.Order Kuantiti: 1 unit
  • Harga: Niaga
  • Pakej: Papan lapis kes
  • Model: SL833
  • Standard: AITM 2,0006, BSS 7322, FAR BAHAGIAN 25 LAMPIRAN F Bahagian IV
  • Detail produk

    produk Tags

    OSU Heat Release Rate Tester Stainless Steel Combustion Test Chamber Equipped

    Maklumat produk  daripada OSU hHeat Release Kadar Tester

    The OSU heat release rate tester approved by FAA of the Federal Aviation Administration of the United States was originally designed by Smith of Ohio State University in 1972, and later became a FAA designated combustion test instrument for testing the heat release rate of Aeronautical materials. The test standards are FAR Part 25 Appendix F Part IV, Airbus AITM 2.00. 06, Boeing BSS 7322.

    ciri-ciri prestasi OSU Heat Release Kadar Tester

    1. Stainless steel combustion test chamber with high temperature glass observation window;
    2. The heat radiation source is 4 Glowbars heating rods, which can provide 35KW/M2 heat radiation flux.
    3. Two independent PID temperature controllers are used for heating temperature control.
    4. Equipped with fully automatic pneumatic sample propulsion device and shielding door device;
    5. Equipped with upper burner and movable lower burner;
    6. Rotor flowmeter can be used to adjust the gas flow rate of upper and lower burners.
    7. Equipped with movable T-type calibration burner device and flow controller;
    8. Mass flow controller is applied to thermopile temperature calibration automatically.
    9. Water-cooled heat flow meter is equipped with cooling mode to measure the heat radiation flux of the fire surface.
    10. The air temperature control device can provide constant temperature and flow air for the test chamber.
    11. The orifice flowmeter is used to measure the flow pressure entering the test bin.
    12. Equipped with data acquisition system and heat release standard test software.

    Produk  parameter of OSU Heat Release Rate Tester

     saiz  760mm (W) x 1850 mm x (H) x 850mm (D)
     Berat  218KG
     keperluan elektrik  220 V, 35 Amps
     Suhu ambien  10 ℃ untuk 35 ℃
     tambahan Gas  Suhu dan Gas Semasa Malar
     gas pembakaran  metana
     standard   AITM 2,0006, BSS 7322, FAR BAHAGIAN 25 LAMPIRAN F Bahagian IV
     aplikasi  Bahan Aviation

     


  • Previous:
  • Seterusnya:

  • Tulis mesej anda di sini dan hantar kepada kami