China OSU Kutentha Kumasulidwa Voterani Tester Opanga ndi ogulitsa | konse

OSU Kutentha Kumasulidwa Voterani Tester

Short Description:

The OSU heat release rate tester approved by FAA of the Federal Aviation Administration of the United States was originally designed by Smith of Ohio State University in 1972, and later became a FAA designated combustion test instrument for testing the heat release rate of Aeronautical materials.


  • Min.Order Kuchuluka: 1 wagawo
  • Price: kudzasintha
  • Phukusi: plywood Mlanduwu
  • Model: SL833
  • Mfundo: AITM 2.0006、BSS 7322、FAR PART 25 APPENDIX F Part IV
  • mankhwala Mwatsatanetsatane

    Tags mankhwala

    OSU Heat Release Rate Tester Stainless Steel Combustion Test Chamber Equipped

    Mankhwala mfundo  za OSU hHeat Kumasulidwa Voterani Tester

    The OSU kutentha mlingo kumasulidwa Tester ovomerezedwa ndi FAA wa Federal Aviation Administration wa United States poyambirira linakonzedwa ndi Smith wa Ohio State University mu 1972, ndipo anadzakhala FAA anasankha kuyaka mayeso chida kudziyesa kutentha mlingo amasulidwe zipangizo Aeronautical. Mfundo mayeso ndi mtunda Part 25 Zakumapeto F Part IV, Airbus AITM 2,00. 06, Boeing BSS 7322.

    Magwiridwe makhalidwe a OSU Kutentha Kumasulidwa Voterani Tester

    1. Stainless steel combustion test chamber with high temperature glass observation window;
    2. The heat radiation source is 4 Glowbars heating rods, which can provide 35KW/M2 heat radiation flux.
    3. Two independent PID temperature controllers are used for heating temperature control.
    4. Equipped with fully automatic pneumatic sample propulsion device and shielding door device;
    5. Equipped with upper burner and movable lower burner;
    6. Rotor flowmeter can be used to adjust the gas flow rate of upper and lower burners.
    7. Equipped with movable T-type calibration burner device and flow controller;
    8. Mass flow controller is applied to thermopile temperature calibration automatically.
    9. Water-cooled heat flow meter is equipped with cooling mode to measure the heat radiation flux of the fire surface.
    10. The air temperature control device can provide constant temperature and flow air for the test chamber.
    11. The orifice flowmeter is used to measure the flow pressure entering the test bin.
    12. Equipped with data acquisition system and heat release standard test software.

    Mankhwala  magawo of OSU Heat Release Rate Tester

     kukula  760mm (W) × 1850mm × (H) × 850mm (D)
     Kunenepa  218KG
     magetsi zofunika  220 V, 35 mikuza mawu
     yozungulira kutentha  10 ℃ 35 ℃
     wothandiza Mafuta  Zonse Kutentha ndi zonse Current Mafuta
     kuyaka gasi  dziko
     Standard   AITM 2,0006, BSS 7322, mtunda GAWO 25 KUMAPETO F Part IV
     Mapulogalamu  Zida ndege

     


  • Previous:
  • Kenako:

  • Lembani uthenga wanu apa ndi kulitumiza ilo kwa ife