China OSU Heat Release Kaʻia Manufacturers a me Suppliers | Skyline

OSU Heat Release Kaʻia

Pōkole Description:

Ke OSU wela hoʻokuʻu ukuʻia i apono ia e FAA o ka Pekelala maunakea noho kia'āina o kaʻAmelika Hui Pūʻia i mua papahana e Smith o Ohio State University i ka makahiki 1972, a ma hope lilo i FAA i koho'ā ho'āʻo mea hana no ka hoao i ka wela hoʻokuʻu uku o Aeronautical mea.


  • Min.Order mea: 1 pa alima
  • Price: Negotiable
  • Makua: Plywood Nānā '
  • Model: SL833
  • Standards: AITM 2,0006, BSS 7322, hiki Mahele 25 i paiiaʻi F Part IV
  • Product Detail

    Product Tags

    OSU Heat Release Rate Tester Stainless Steel Combustion Test Chamber Equipped

    Product 'ike  o OSU hHeat Release Kaʻia

    The OSU heat release rate tester approved by FAA of the Federal Aviation Administration of the United States was originally designed by Smith of Ohio State University in 1972, and later became a FAA designated combustion test instrument for testing the heat release rate of Aeronautical materials. The test standards are FAR Part 25 Appendix F Part IV, Airbus AITM 2.00. 06, Boeing BSS 7322.

    Auana ano o OSU Heat Release Kaʻia

    1. Stainless steel combustion test chamber with high temperature glass observation window;
    2. The heat radiation source is 4 Glowbars heating rods, which can provide 35KW/M2 heat radiation flux.
    3. Two independent PID temperature controllers are used for heating temperature control.
    4. Equipped with fully automatic pneumatic sample propulsion device and shielding door device;
    5. Equipped with upper burner and movable lower burner;
    6. Rotor flowmeter can be used to adjust the gas flow rate of upper and lower burners.
    7. Equipped with movable T-type calibration burner device and flow controller;
    8. Mass flow controller is applied to thermopile temperature calibration automatically.
    9. Water-cooled heat flow meter is equipped with cooling mode to measure the heat radiation flux of the fire surface.
    10. The air temperature control device can provide constant temperature and flow air for the test chamber.
    11. The orifice flowmeter is used to measure the flow pressure entering the test bin.
    12. Equipped with data acquisition system and heat release standard test software.

    Product  kiko'î of OSU Heat Release Rate Tester

     Size  760mm (W) m 1850mm m (H) m 850mm (D)
     Weight  218KG
     uila koi  220 V, 35 Amps
     Ambient wela  10 ℃ i 35 ℃
     kākoʻo Ke Kinoea  Mau Mahana a me ka ikaika Hawaii Ke Kinoea
     'ā kinoea  methane
     hae   AITM 2,0006, BSS 7322, hiki Mahele 25 i paiiaʻi F Part IV
     noi  maunakea Nā Pono Hana

     