TSín OSU Teas Scaoileadh Ráta Tester, Áise Láithreán Gréasáin | Skyline

OSU Teas Scaoileadh Ráta Tester

Cur síos achomair:

The OSU heat release rate tester approved by FAA of the Federal Aviation Administration of the United States was originally designed by Smith of Ohio State University in 1972, and later became a FAA designated combustion test instrument for testing the heat release rate of Aeronautical materials.


  • Min.Order Quantity: 1 Aonad
  • Praghas: shoshannta
  • Pacáiste: Plywood Cás
  • Model: SL833
  • caighdeáin: AITM 2.0006、BSS 7322、FAR PART 25 APPENDIX F Part IV
  • Sonraigh Táirge

    Táirge Clibeanna

    OSU Heat Release Rate Tester Stainless Steel Combustion Test Chamber Equipped

    Faisnéis faoi tháirgí  de OSU hHeat Scaoileadh Ráta Tester

    An tástálaí ráta scaoilte teasa OSU ceadaithe ag FAA an Eitlíochta Chónaidhme Riaracháin na Stát Aontaithe a bhí ceapadh ar dtús ag Smith an Ollscoil Stáit Ohio i 1972, agus ina dhiaidh sin tháinig chun bheith ina ionstraim tástála dócháin FAA sainithe le haghaidh tástála an ráta scaoilte teasa na n-ábhar Aerloingseoireachta. Tá na caighdeáin tástála FAR Cuid 25 Aguisín F Cuid IV, Airbus AITM 2.00. 06, Boeing BSS 7322.

    Saintréithe feidhmíochta de OSU Teas Scaoileadh Ráta Tester

    1. Stainless steel combustion test chamber with high temperature glass observation window;
    2. The heat radiation source is 4 Glowbars heating rods, which can provide 35KW/M2 heat radiation flux.
    3. Two independent PID temperature controllers are used for heating temperature control.
    4. Equipped with fully automatic pneumatic sample propulsion device and shielding door device;
    5. Equipped with upper burner and movable lower burner;
    6. Rotor flowmeter can be used to adjust the gas flow rate of upper and lower burners.
    7. Equipped with movable T-type calibration burner device and flow controller;
    8. Mass flow controller is applied to thermopile temperature calibration automatically.
    9. Water-cooled heat flow meter is equipped with cooling mode to measure the heat radiation flux of the fire surface.
    10. The air temperature control device can provide constant temperature and flow air for the test chamber.
    11. The orifice flowmeter is used to measure the flow pressure entering the test bin.
    12. Equipped with data acquisition system and heat release standard test software.

    Táirge  paraiméadair of OSU Heat Release Rate Tester

     Méid  760mm (W) x 1850mm x (H) x 850mm (D)
     meáchan  218KG
     ceanglais Leictreachais  220 V, 35 Amps
     Teocht chomhthimpeallach  10 ℃ go 35 ℃
     cúnta Gas  Teocht tairiseach agus Constant Gáis reatha
     dócháin gáis  meatán
     Caighdeán   AITM 2.0006, BSS 7322, FAR CUID 25 AGUISÍN F Cuid IV
     Iarratais  Ábhair Eitlíochta

     


  • Roimhe Seo:
  • : Ar Aghaidh

  • Scríobh do theachtaireacht anseo agus seol chugainn é