Tsieina OSU Gwres Wasg Cyfradd Gweithgynhyrchwyr a Chyflenwyr Tester | Skyline

OSU Gwres Wasg Cyfradd Tester

Disgrifiad byr:

Mae'r profwr cyfradd rhyddhau gwres OSU gymeradwyo gan FAA y Hedfan Ffederal Gweinyddu yr Unol Daleithiau a ddyluniwyd yn wreiddiol gan Smith o Ohio State University yn 1972, ac yn ddiweddarach daeth yn offeryn prawf hylosgi FAA dynodedig ar gyfer profi cyfradd rhyddhau gwres o ddeunyddiau Awyrennol.


  • Min.Order Nifer: 1 uned
  • Pris: i'w drafod
  • Pecyn: Pren haenog Achos
  • Model: SL833
  • Safonau: AITM 2.0006, BSS 7322, YN HYN RHAN 25 ATODIAD F Rhan IV
  • Manylion cynnyrch

    cynnyrch Tags

    OSU Heat Release Rate Tester Stainless Steel Combustion Test Chamber Equipped

    Gwybodaeth am y cynnyrch  o OSU hHeat Rhyddhau Cyfradd Tester

    The OSU heat release rate tester approved by FAA of the Federal Aviation Administration of the United States was originally designed by Smith of Ohio State University in 1972, and later became a FAA designated combustion test instrument for testing the heat release rate of Aeronautical materials. The test standards are FAR Part 25 Appendix F Part IV, Airbus AITM 2.00. 06, Boeing BSS 7322.

    Nodweddion perfformiad OSU Gwres Wasg Cyfradd Tester

    1. Stainless steel combustion test chamber with high temperature glass observation window;
    2. The heat radiation source is 4 Glowbars heating rods, which can provide 35KW/M2 heat radiation flux.
    3. Two independent PID temperature controllers are used for heating temperature control.
    4. Equipped with fully automatic pneumatic sample propulsion device and shielding door device;
    5. Equipped with upper burner and movable lower burner;
    6. Rotor flowmeter can be used to adjust the gas flow rate of upper and lower burners.
    7. Equipped with movable T-type calibration burner device and flow controller;
    8. Mass flow controller is applied to thermopile temperature calibration automatically.
    9. Water-cooled heat flow meter is equipped with cooling mode to measure the heat radiation flux of the fire surface.
    10. The air temperature control device can provide constant temperature and flow air for the test chamber.
    11. The orifice flowmeter is used to measure the flow pressure entering the test bin.
    12. Equipped with data acquisition system and heat release standard test software.

    Cynnyrch  paramedrau of OSU Heat Release Rate Tester

     maint  760mm (W) x 1850mm x (H) x 850mm (D)
     pwysau  218KG
     gofynion trydan  220 V, 35 amp
     tymheredd amgylchynol  10 ℃ i 35 ℃
     ategol Nwy  Tymheredd Cyson a Cyson Nwy Gyfredol
     nwy hylosgiad  methan
     safonol   AITM 2.0006, BSS 7322, YN HYN RHAN 25 ATODIAD F Rhan IV
     ceisiadau  Deunyddiau hedfan

     


  • Blaenorol:
  • : Nesaf

  • Ysgrifennwch eich neges yma ac anfon atom