Horizontal a Vertikal Flammability Testen Machine UL 94 Flam Chamber. Horizontal Flam Chamber, vertikalen Flam Chamber Fir d'flammability Testen vun Plastik Materialien an Konsument elektreschen Apparaten an Apparater benotzt. STAINLESS Stolkonstruktioun mat schwaarz bannen a grousse hëlze Fënster fir einfach ukuckt. Ëmfaasst eng voll metallen specimen Ënnerstëtzung an Präzisioun Gas Flux Kontrollen.
Produit Parameteren vun der Horizontal a Vertikal Flammability Testen Machine
Timer | 0-999.9s +/- 0.1s (metallen) |
Flam Héicht | 20mm +/- 2mm bis 180mm +/- 10mm (metallen) |
Gas | 98% Methan |
Temperatur Testen Rei | 0-1000degree |
Dimensiounen (L * W * H) | 1100 x 700 x 1300mm |
Gewiicht | 128kg |
Standarden | UL 94-2006 IEC 60695-11-3 IEC 60695-11-4 |
Produit Spillfilmer an Uwendung vun der Horizontal a Vertikal Flammability Testen Machine
Testen Bestëmmungen
UL 94-2006 IEC 60695-11-3 IEC 60695-11-4
UL94: Tester fir Flammability vun Plastic Materialien Parts an Apparater ausgefouert Apparater
UL94HB: Horizontalen Burning Test
V-0,1,2: 20mm Vertikal Burning Test
94-5VA, B: 500W (125mm) Vertikal Burning Test
94VTM-0,1,2: dënn Material Vertikal Burning Test
94HBF, 94HF-1,2: Horizontalen Burning geschaimte Material Test
60695-11-10 IEC: Fire iwwerschloen Testen - Part 11-10: Test gebrannt - 50 W horizontal a vertikal Flam Test Methoden
60695-11-20 IEC: Fire iwwerschloen Testen - Part 11-20: Test gebrannt - 500 W Flam Test Methoden
60695-11-4 IEC: Fire iwwerschloen Testen - Part 11-4: Test gebrannt - 50 W gebrannt-Staatsapparat an conformational Test Method
60695-11-3 IEC: Fire iwwerschloen Testen - Part 11-3: Test gebrannt - 500 W gebrannt-Staatsapparat an conformational Test Method
Produit Detailer vun der Horizontal a Vertikal Flammability Testen Machine
Kinds |
500W(5V class ) / 50W(HB/Vclass) |
Test Flame |
500W(burning test for V-0,V-1,V-2 classification) / 50W(burning test for V-0,V-1,V-2 classification) |
Burner Tube |
Internal diameter |
Φ 9.5mm±0.3mm Internal diameter |
Φ 9.5mm±0.3mm, |
Burning Angle |
0°,20°,45° / 0°,20°,45° |
Thermocouple |
Type K (Ni/Cr - Ni/Al) / Type K (Ni/Cr - Ni/Al) |
Thermocouple Size |
0.5 mm X 0,5 mm |
Standard Koffer Block |
9mm±0.01mm/ 5.5mm ± 0.01mm, |
W eight |
10g±005g before drilling. 76g±0.01g before drilling. |
Time for Temperature to Increase |
From 100°C±5°C to 700°C±3°C; 54s±2s (preset); / From 100°C±5°C to 700°C±3°C; 44s±2s (preset) |
Gas Flow |
965±32ml/min/ 105±10ml/min |
Gas Supply |
methane,min.98% purity / methane,min.98% purity |
Water-column |
125m±5mm ‹10mm |
Test Time |
54±2s/ 44±2s |
Flame Height Indicator |
40±1mm/ 20 ± 1mm |
Volume Of Chamber |
>0.5m³, black interior / >0.5m³, black interior |
What is the UL 94 standard for flammability of plastics?
The UL standard classifies plastics according to the minimum thickness at which it stops burning when tested in a horizontal or vertical orientation. Types of testing/flammability ratings covered in the UL 94 standard for flammability of plastic materials include: Vertical burning tests (V-0, V-1, V-2, 5V, 5VA, 5VB, VTM-0, VTM-1, VTM-2)
What is UL94 Horizontal & Vertical Flammability Tester?
UL94 Horizontal & Vertical Flammability Tester is a testing device which is utilized to conduct the Standard test for ensuring the Flammability performance of Plastic Materials which are used for Parts in Devices and Appliances. This is to note that the test doesn’t show the real hazards faced by the specimen in real-life fire accidents.