China Fourier Infrared Anwụrụ ọkụ toxicity Analysis System Manufacturers na Suppliers | skyline
industrial sewing machine

Fourier Infrared Anwụrụ ọkụ toxicity Analysis System

Short Description:

The flue gas nwere ike sampled na elu okpomọkụ na nyochara na-egosi na elu okpomọkụ, na qualitative na quantitative analysis nwere ike rụrụ online.


  • Min.Order ibu: 1 unit
  • Ahịa: Okwukwe
  • Ngwugwu: Plywood Case
  • Model: SL829
  • Standards: DIN 5510-2, ISO 19702: 2015, CSN EN 45545-2 + A1: 2015, Imo FTPC Part 2
  • Product Ihe

    Product Tags

    DIN 5510-2  FTIR Fourier m nfrared S moke T oxicity A nalysis S ystem

    Product iwebata nke  FTIR Fourier m nfrared S moke T oxicity A nalysis S ystem

    FTIR Fourier Infrared toxicity Analysis System, mepụtara maka online anwụrụ ọkụ mejupụtara analysis, na NBS Anwụrụ ọkụ njupụta Test Box (ISO 5659-2) mode, osobo DIN5510-2, EN 45545-2 na ISO 19702 ule ụkpụrụ. The flue gas nwere ike sampled na elu okpomọkụ na nyochara na-egosi na elu okpomọkụ, na qualitative na quantitative analysis nwere ike rụrụ online. The ụdị nke gas nyochaa gụnyere, mana na-ejedebeghị na, na-esonụ ụdị: CO2, CO, SO2, HCL, HBR, HCN, HF, NOX, na dị ka.

    Product afọ nke FTIR Fourier m nfrared S moke T oxicity A nalysis S ystem

    1. mmesho ụkpụrụ: Fourier gbanwee infrared
    2. Zero nwayọọ: akpaka mgbazi
    3. iche nwayọọ: dịghị
    4. Linear ndiiche: ≤ 2% FS {24h}
    5. Response oge (T90) ≤ l20s tupu flue gas ọgwụgwọ; ≤ l20s mgbe flue gas ọgwụgwọ.
    6. Protection larịị: lP65
    7. CaroUsel interferometer

    Mkpebi: 8cm-1 ịgụ isiokwu ọsọ: 10 ugboro 1 abụọ Detector: Peltier obi jụrụ MCT Infrared isi: Sic, l550K Doo splitter: BaF2 Ohere: BaF2 Wavelength nso: 900 - 4200crn-1
    8.Sample gas ulo Sample Cell
    arụ ọrụ okpomọkụ: l80 Celsius C Multiple echiche ụzọ ogologo: 2.5m ihe: 100% gold mkpuchi
    Mirror: ofu, gold ntekwasa Volume: 1.07L interface: Swagelok 6 rnm orll4 "Akara: Viton. 0-ring5
    9. The data interface
    Communication: RS-232 D ụdị 9 oghere
    10. nlele
    nlele mgbapụta: mpụga sample eruba chọrọ: 2-I0L / min Ájá filtration chọrọ: 2U sample gas mgbali chọrọ: ikuku
    11. Wuru na-data nhazi
    Enyem Ntụgharị: Dynamic iche 95 dB Signal Processor: 32-bit-ese n'elu mmiri Point DSP Operation Speed: 120 MFLOPS
    12. Power: 220VAC, 50HZ

    Product Njirimara na Ngwa nke  na FTIR Fourier m nfrared S moke T oxicity A nalysis S ystem

    1. The ule ụkpụrụ bụ Fourier gbanwee infrared analysis;
    2. Mid-infrared full ụdịdị dị iche iche analysis, spektral nso: 900-4200 cm-1.
    3. Mkpebi: 8 cm-1, ahụkarị nchọpụta akara: 1ppm, interferometer ịgụ isiokwu ọsọ: ugboro 10 / sec;
    4. Detector: Peltier obi jụrụ MCT, infrared ìhè isi: SiC150K, doo splitter: ZnSe (mmiri na-àmà ihe onwunwe);
    5. mmesho ziri ezi: ± 2% nke zuru ọnụ ọgụgụ;
    6. arụ ọrụ okpomọkụ: 180 ° C, multiple echiche ngwa anya ụzọ: 5.0m;
    7. 2 ma ọ bụ karịa ájá filtration (2μm);
    8. Iji mmiri na-àmà ngwa anya window ihe onwunwe, adabara mmiri na-arụ ọrụ na gburugburu ebe obibi;
    9. The data nwere ike nọgidere na-anwale a ogologo oge, na-ebi ndụ iche iche na data nwere ike nọgidere na-dere na dere, na akụkọ ihe mere eme data nwere ike na-egwuri azụ;
    10. The gas-ulo na ihe onwunwe na-ntekwasa na gold mkpuchi, antimony mkpuchi na corrosion na-eguzogide gas (HCL, HCN, NH3);
    11. ike tụọ H2O ruo 40% nke ngwakọta, na-adịgide adịgide zọpụta spektral Ọbá akwụkwọ, mgbe mmezi nke factory gas mmiri, ọ dịghị mkpa recalibrate;
    12. Response oge T90 <12s;
    13. The usoro nile nke kpo oku, mgbe nile okpomọkụ akara;
    14. ike na-akpaghị aka mepụta okpomọkụ na nsogbu ụgwọ, arụmọrụ friendly;
    15. Low mmezi eri, dịghị sample ọnwụ na ịgbanwe thermal nlele usoro, n'ụzọ zuru ezu akpaka ule usoro zuru ezu nchekwa ọrụ, n'ụzọ zuru ezu modular usoro iji hụ na kacha mgbanwe;
    16. Tupu ụfọdụ unit, ọ dịghị mkpa ka itughari na dehydrate na sample gas, na n'akụkụ nile na-ewe iwe 180 ° C;
    17. Ofụri Esịt izute ISO 19702 na EN 45545-2 ụkpụrụ.

    Product Nkọwa nke na FTIR Fourier m nfrared S moke T oxicity A nalysis S ystem

    The Ft-Iye toxicity Analysis System mejupụtara atọ components: ISO 5659-2 Anwụrụ ọkụ njupụta Box, Gas nlele Pretreatment, na Fourier ịgbanwe Infrared analyzer. The nlele pretreatment si dị nnọọ iche na ot usoro na ihe nile nke ya mmiri na-ejikwara na a elu okpomọkụ nke 180 ° C na-enweghị wepụ mmiri. The analysis nke Fourier gbanwee infrared analyzer na-thermostated na 180 Celsius C. The isi mmiri bụ ìhè isi, sample cell, interferometer na detector. The interferometer modulates na infrared laser ọcha ìhè na-enyocha kwa na gas sample na-nyochaa. Ebe ọ bụ na ngwa anya ọwa nke sample cell bụ ruo 7 mita ogologo, ihe magburu onwe mgbaàmà nwere ike nwetara, na etinye obi gị dum modulated ìhè mgbaàmà na-akpọ DTGS. The infrared monitor na-eji maka nchọpụta. Achọpụtara infrared ụdịdị dị iche iche ihe mgbaàmà na-jiri ya tụnyere ọkọlọtọ ụdịdị dị iche iche na kọmputa database mgbe a doro Fourier gbanwee nhazi site a na kọmputa, na mmiri na gas sample na-qualitatively na quantitatively nyochara.

    Standards:

    DIN 5510-2
    ISO 19702: 2015
    CSN EN 45545-2 + A1: 2015
    Imo FTPC Part 2
    Dimension: Test usu: 900mm (W) x 1750mm x (H) x 700mm (D)
    arọ: 138kg

    nwụnye chọrọ

    Power chọrọ: 220 V, 10 Amps
    Ihere okpomọkụ: 10 ° C na 35 ° C
    Inyeaka gas: ikuku Compressor gas (ma ọ bụrụ na-onwem na nitrogen generator)