China SL-FL28 Roof Material Fire Reactivity Test Device Manufacturers and Suppliers | Skyline
industrial sewing machine

SL-FL28 Roof Material Fire Reactivity Test Device

תיאור קצר:

הארגון הבינלאומי ISO תקינה: ISO 12,468-1: B - 2013, ISO 12,468-1: C - 2013

EN התקן האירופי: ENV 1187: T1: 2002

מידות: 2100mm (אורך) x 1900mm x (H) x 900mm (W)

משקל: 318KG


  • כמות Min.Order: 1 יחידה
  • מחיר: סחיר
  • אריזה: נרתיק עץ לבוד
  • דגם: SL-FL28
  • תקנים: ISO 12,468-1: B - 2013, ISO 12,468-1: C - 2013, ENV 1187: T1: 2002
  • פרטי מוצר

    תגיות מוצר

    ISO 12468-1 Roof Material Fire Reactivity Test Device with Computer and Printer Devices and Standard Test Software

    הקדמת מוצרים של  Roof M aterial F ire R eactivity T est D evice
    The Roof Material Fire Reactivity Test Device
     is developed according to the preparation of GB/T 30735-2014 "external fire reaction test method of roof and roof covering products", the test method is mainly referring to the T1 test method of Env 1187 and ISO 12468-1, this method stipulates 3 kinds of test methods under the condition of ignition , method a corresponds to T1 in Env 1187, and Method B and method C correspond to ISO 12468-1. The state of the external fire reaction of roof and roof covering products was simulated under the action of wind blowing and heat radiation.

    פרמטרי מוצרים של  Roof M aterial F ire R eactivity T est D evice
    1.The test specimen frame structure, adopts the metal square tube welding and the angle steel;
    2.Test sample frame test angle can be adjusted, the use of pneumatic adjustment, the user only need key-type operation, user-friendly;
    3.The test bracket angle adjustable range is 0-50 degrees, satisfies the ISO 12468 method A as well as the ENV 1187 T1 to the specimen maximum tilt height is 45 degrees the test request;
    4.Duct material for SUS304 stainless steel, thickness of 2 mm, the upper air duct installed with a fine honeycomb type grille, the exit of the coarse honeycomb grille;
    5.Wind turbine Specifications: Wind speed maximum of 250 cubic meters min, fan motor power 5.5KW;
    6.Fan Frequency control device: 3 phase 380V power 5.5KW;
    7.The air duct adopts ball screw, servo motor drive mode, can adjust angle automatically;

    Product Feature and Application of the Roof M aterial F ire R eactivity T est D evice

    1.Air Duct Adjustable angle range of 0-35 degrees, to meet the ISO 12468 method B and Method C;
    2.Equipped with impeller-type wind speed meter 3, precision for 0.1m/s;
    3.Radiant surface size of radiation plate is 600mmx600mm;
    4.Ignition method using spark ignition mode, while providing thermocouple monitoring radiant plate surface temperature state, when the radiation plate appears extinguished, the gas can be automatically cut off, to avoid combustion in the state of the gas leakage;
    5.To provide small stainless steel tube burner, can be used in wood shavings combustion test;
    6.Wood duo Fire Gas burning device 1 sets;
    7.Provide video surveillance device 2 sets.

    פרטי מוצר של  the Roof M aterial F זעמם R eactivity T EST D evice

    תקנים

    ISISO 12468-1: B - 2013,ISO 12468-1: C – 2013

    ENV 1187:t1:2002
    דרישות התקנה

    Power requirements

    220 V, 50 Amps; 380V, 15KW

    טמפרטורת הסביבה

    10 ° C to 35 ° C

    גז בעירה

    פרופן

    Dimension

    2100mm (L) x 1900mm x (H) x 900mm (W)

    משקל

    318KG