100% Original Sharp Edge Tester - UL94 Flame Chamber – Skyline

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have been ready to share our knowledge of internet marketing worldwide and recommend you suitable merchandise at most aggressive rates. So Profi Tools present you very best price of money and we are ready to develop alongside one another with Ul1685 Vertical Tray Test Chamber For Cables , Cable Vertical-Tray Flammability Testing Apparatus , Surface Spead Flame Tester for Building Materials , Warmly welcome to cooperate and develop with us! we are going to continue to provide product or service with high quality and competitive rate.
100% Original Sharp Edge Tester - UL94 Flame Chamber – Skyline Detail:

UL94 Flame Chamber for Test Measures the Burning Rate of Samples Positioned

Product introduction of the UL94 Flame Chamber

The test is widely applied throughout industry, especially in electrical manufacturing, where it is widely used for the testing of electrical products. The test measures the burning rate of samples positioned either horizontally or vertically.

Product parameters of the UL94 Flame Chamber

 Kinds  500W(5V class )  50W(HB/Vclass)
 Test Flame  500W(burning test for V-0,V-1,V-2 classification)  50W(burning test for V-0,V-1,V-2 classification)
 Burner Tube  Internal diameter: Φ 9.5mm±0.3mm  Internal diameter: Φ 9.5mm±0.3mm,
 Burning Angle  0°,20°,45°  0°,20°,45°
 Thermocouple  Type K (Ni/Cr – Ni/Al)  Type K (Ni/Cr – Ni/Al)
 Thermocouple Size  0.5 mm  0.5 mm
 Standard Copper Block  9mm±0.01mm,
weight:10g±0.05g before drilling.
 5.5mm±0.01mm,
weight:76g±0.01g before drilling.
 Time for Temperature to Increase  From 100°C±5°C to 700°C±3°C; 54s±2s (preset)  From 100°C±5°C to 700°C±3°C;
44s±2s (preset)
 Gas Flow  965±32ml/min  105±10ml/min
 Gas Supply  methane,min.98% purity  methane,min.98% purity
 Water-column  125m±5mm  ‹10mm
 Test Time  54±2s  44±2s
 Flame Height Indicator  40±1mm  20±1mm
 Volume Of Chamber  >0.5m³, black interior  >0.5m³, black interior
 Conform to standard  UL94,IEC60695-11-3,IEC60695-11-20  UL94,IEC60695-11-4,IEC60695-11-10

Product Feature and Application of the UL94 Flame Chamber

1.The test chamber volume is greater than 0.75 cubic meters, and the inner wall of the box is black;
2.Ultra-large transparent observation window for easy observation of the combustion state of the sample;
3.User-designed door opening method for easy access to specimens and burners;
4.The burner angle can be easily adjusted at 0, 20, 45 degrees to meet the needs of various standards;
5.Provide Bunsen burner source, in accordance with ASTM D5025 standard;
6.The panel timer device can record information such as test time;
7.Providing a rotameter to regulate the flow of combustion gases;
8.High-precision pressure regulating valve to adjust the standard gas pressure required;
9.Fan burner, in accordance with ASTM D4986;
10.A top exhaust device that extracts exhaust gas generated by combustion;
11.Optional burner calibration system is available to ASTM D5207.

Product Details of the the UL94 Flame Chamber

The UL94 horizontal vertical burner adopts the full standard satisfaction design concept and considers many test standards and is integrated into one test box. The horizontal vertical burner is designed to test the UL standard flammability performance of equipment and appliance parts materials. Test indicators for end use such as flammability, burning rate, flame spread, burning strength and flame retardancy of the product can be tested.
It conforms to all five UL 94 horizontal and vertical burner tests and associated ASTM international standards. There are:
Horizontal Burning Test; UL 94HB (ASTM D 635, IEC 60695-11-10, IEC 60707, ISO 1210).
Vertical Burning Test: UL 94 V-0, V-1, or V-2 (ASTM D 3801, IEC 60695-11-10, IEC 60707, ISO 1210).
Vertical Burning Test: 5VA or 5VB (ASTM D 5048, IEC 60695-11-20, IEC 60707, ISO 9772).
Thin Material Vertical Burning Test: VTM-0, VTM-1, or VTM-2 (ASTM D 4804, ISO 9773).
Horizontal Burning Foamed Material Test: HF- 1, HF-2 or HBF (ASTM D 4986, ISO 9772).
Burners (ASTM D 5025, ASTM D 5207, ISO 10093, ISO 103351)
Standards:ISO:ISO 9772,ISO 9773 IEC:IEC 60695-11-10:2013 UL:UL94

Dimension:950 mm (W) x 850 mm (D) x 1350 mm(D)

Weight:58kg

Installation requirements
Electrical: 110V AC 60Hz / 230V AC 50Hz
Ambient Temperature: Operating 10°C to 35°C
Gas Supplies: Propane Gas or Methane Gas


Product detail pictures:

100% Original Sharp Edge Tester -
 UL94 Flame Chamber – Skyline detail pictures

100% Original Sharp Edge Tester -
 UL94 Flame Chamber – Skyline detail pictures

100% Original Sharp Edge Tester -
 UL94 Flame Chamber – Skyline detail pictures


Related Product Guide:

Our well-equipped facilities and great excellent command throughout all stages of generation enables us to guarantee total customer fulfillment for 100% Original Sharp Edge Tester - UL94 Flame Chamber – Skyline , The product will supply to all over the world, such as: Mexico , Serbia , Cambodia , We pursue the management tenet of "Quality is superior, Service is supreme, Reputation is first", and will sincerely create and share success with all clients. We welcome you to contact us for more information and look forward to working with you.
  • Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Alan from venezuela - 2017.05.21 12:31
    We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
    5 Stars By Dora from Zurich - 2018.06.26 19:27
    Write your message here and send it to us