Pulou Mu Saina Mu tetee Gaosi Combustion Tofotofoga ma e tuuina | tafailagi

Tetee afi afi pulou Tofotofoga Combustion

Faamatalaga puupuu:

Afi puloutau o le afi-e tetee masini suega combustion e atiina ae e tusa ai ma NFPA 1971-2007 tulaga suega. Ona mataupu faavae tofotofoga e faapea i lalo o le gaoioiga o le leisa vevela, aafiaga tatala afi i vaega eseese o le puloutau o le afi, ona detects lona faatinoga afi-retardant.


  • Min.Order Aotelega: 1 iunite
  • Tau: o feagaiga tau tupe
  • Afifi: Mataupu Plywood
  • Faataitaiga: SL849
  • Tulaga Faatonuina: GA 44:2004、NFPA 1971-2007: 8.3
  • Faamatalaga oloa

    pine o oloa

    NFPA 1971-2007 Fire Helmet Fire Resistance Combustion Test Device

    Talaaga otooto oloa o le meafaitino e tetee Mu pulou Mu Combustion Tofotofoga

    Afi puloutau o le afi-e tetee masini suega combustion e atiina ae e tusa ai ma NFPA 1971-2007 tulaga suega. Ona mataupu faavae tofotofoga e faapea i lalo o le gaoioiga o le leisa vevela, aafiaga tatala afi i vaega eseese o le puloutau o le afi, ona detects lona faatinoga afi-retardant.

    Faatinoga o Galuega uiga o le meafaitino e Tofotofoga tetee Combustion Mu pulou Mu

    1. The radiation heat source is steel heating pipe. The temperature of heating pipe can be adjusted by using PID temperature control mode, so as to adjust the heat radiation flux. The heat radiation flux can be controlled in the range of 10 kW/m2+1 kW/m2, and the heat radiation flux can be accurately adjusted to 0.1 kW/m2.
    2. Imported water-cooled heat flow meter is used to monitor the heat radiation output flux. The measuring range of water-cooled heat flow is 0-50kW/m2.
    3. Equipped with self-circulating cooling water device, the surface temperature of water-cooled heat flowmeter can be taken away to achieve protection function.
    4. Provide secondary instruments to display the value of heat radiation flux.
    5. The burner is a lamp device with a nozzle diameter of 13 mm+3 mm.
    6. Provide gas secondary decompression device to provide stable gas pressure;
    7. By adjusting the gas flow rate with a rotor flowmeter, the flame temperature can be controlled in the range of 1100 ~1300 C.
    8. A K-type thermocouple is equipped to measure the temperature at the tip of the inner flame and provide a secondary instrument to display the flame temperature value.
    9. Equipped with time relay, the test time of burning flame of Bunsen lamp can be controlled for 15 seconds.
    10. Equipped with time timer, it can record the duration of flame continuation of cap and shell.
    11. The radiation source is shielded by pneumatic baffle to avoid the radiation test sample. When the test begins, it opens automatically and closes automatically after the test ends.
    12. The radiation heat source radiates directly to the top of the helmet, and the height of the specimen can be adjusted.
    13. Equipped with a metal head die that meets the average requirement of GB/T 2428-1998 "Adult Head and Face Size";
    14. The metal die is installed in the test cabin and the height can be adjusted manually.
    15. Metal die can adjust left and right position by Y axis.
    16. The height of the Bunsen lamp device can be adjusted manually according to the height of the helmet when it is placed at 45 degrees.
    17. The burner can be moved to the middle part of the high point of the helmet and automatically cut off the combustion gas source after 15 seconds.
    18.The combustion area is equipped with closed tempered glass observation door, which can be used for the tester to observe the test process and avoid the interference of external gas flow.

    Oloa  le faataamilosaga o le Fire Helmet Fire Resistance Combustion Test Device 

     tūlaga  GA 44: 2004, NFPA 1971-2007: 8.3
     talosaga  saogalemu Puipuiga
     fua  1,400 mm (W) X 700 mm (D) X 1,800 mm (H)
     mamafa  215KG
     manaoga eletise  220V, 30A
     kasa manaoga  kasa alu i le kesi

  • Talu:
  • Sosoo ai:

  • Tusi lau savali iinei ma auina mai ia i tatou