Kina Window Brann testenheten Produsenter og leverandører | skyline

Vindu Brann Test Device

Kort beskrivelse:

Vinduet branntestmodell simulerer en vertikal bygningsoverflate som består av en hovedvegg og en sub-vegg vinkelrett på denne.


  • Min.Order Antall: 1 enhet
  • Pris: Etter avtale
  • Pakke: Plywood sak
  • Modell: SL826
  • Standarder: BS 8414-1: 2002, GB / T 29416: 2012
  • Produkt detalj

    Produkttagger

    Vindu Brann Test Enhet for Modellen simulerer vertikale bygningsoverflater

    Produkt innføring av  Vindu Brann Test Device

    The window fire test model simulates a vertical building surface consisting of a main wall and a sub-wall perpendicular to it. The external thermal insulation system is installed on the building surface. The opening of the combustion chamber at the bottom of the test model simulates the window or opening of the floor in the actual building, and the ignited wood. Or the flame of the gas overflows from the window, simulates the attack of the external thermal insulation system when the flame after the bombardment overflows from the window or the hole in the room, checks the damage degree of the external thermal insulation system, and determines the flame propagation property. The test fire source uses about 400 kg of wood, the total heat released in 30 minutes is about 4500 MJ, and the peak heat release rate is about (3 ± 0.5) MW.

    Produkt parametere for  Vindu Brann Test Device

    1. The test system provides an ignition reminder alarm after 5 minutes. When it is ignited, it automatically determines the test start time. At the same time, it can automatically judge the test over temperature. At the same time, the computer can video display the burning test status, and the computer software can record the dripping. Time, collapse time, temperature value and other test related information such as temperature curve;
    2. One wind speed sensor, 0-10M/S, with an accuracy of 0.1M/S;
    3. 2 cameras, including 2 sets of computer display devices;
    4. K-type thermocouple: with stainless steel jacket, temperature range is 0-1038 degrees, temperature accuracy ± 0.1%, thermocouple wire 500 feet;

    Produkt Funksjon og Bruk av  Vindu Brann Test Device

    1. ADAM-4118 module: Rugged 8-channel thermocouple input module, 8 channels of independently configurable differential channels; wide temperature operation; wider operating temperature: -40-+85 °C; high noise immunity: 1kV surge Protection voltage input, 3KV EFT and 8KV ESD protection; strong anti-interference: 1KV surge protection at power input, 3KV EFT, 8KV ESD protection, wide power input range: +10~ +48VDC; input range: +10~+ 48 VDC;
    2. 2 computers;
    3. 3 electric control boxes;
    4. One signal conversion box;
    5. Field wiring.

    Produkt Detaljer om  Vindu Brann Test Device

    Standarder
    BS 8414-1: 2002
    GB / T 29416: 2012
    Building eksteriør: 9m høy
    installasjonskrav
    Elektriske krav: 220 V, 50HZ, 5A
    Romtemperatur: temperatur 10 ° C til 35 ° C, fuktighet (65 ± 5)%


  • Forrige:
  • Neste:

  • Skriv din melding her og send det til oss